The
LVN-2000 uses a vacuum source such as an injector or a Water
Champ® chemical induction mixer to draw the chemical from
the supply tank to the point of application. Utilizing the
extremely reliable and field proven Wallace & Tiernan
V-Notch control valve, reliable feedrates can be maintained
with either manual or automatic control schemes using the
SCU or PCU controllers. A direct reading flowmeter provides
accurate indication of feedrate in GPH or LPH. An optional
4-20 mA output or a high/low flow alarm is available to ensure
reliable operation under all operating conditions.
|
 |
 |
RELIABLE
SODIUM HYPOCHLORITE FEEDING
Unaffected by out-gassing or ait-binding concerns that could
be a problem for conventional metering pumps.
INTEGRAL
FLOWMETER
Direct reading, visual indication of chemical feedrate. Dual
scale rotameter in GPH and LPH. Optional 4-20 mA output is available
for remote indication and recording of feedrate. An alternative
option is a high/low flow alarm that can be used for flow/no-flow
status indication. |
WALL-MOUNTED
CONSTRUCTION
The Panel mounted design saves space and simplifies installation.
Components are mounted at the ideal height for operator convenience.
An easily removable cover provides quick access for any service
requirments.
WIDE
CAPACITY AND OPERATING RANGE
Capacities from 0.66 to 462 GPH. Operating ranges are 10:1 for
capacities up to 11 GPH and 12:1 for capacities from 21 to 462
GPH. |
 |
CAPACITY
GPH(LPH):
0.66 (2.5), 2 (8), 4 (16) , 6 (24), 11 (40), 21 (80),
32 (120), 53 (200), 106 (400), 132 (500),
225 (850), 357 (1350), 462 (1750)
OPERATING RANGE:
10:1 : 0.66 GPH - 11 GPH
20:1 : 21 GPH - 462 GPH
CHEMICALS:
Sodium Hypochlorite
Sodium Bisulphite
VOLTAGE:
Controller requires 120 volts +/- 10% (200mA) or 230 volts +/-
10% (100 mA), 50/60 Hz, single phase. There may be other requirments;
solenoid valves for start-stop service, booster pumps
OPERATING VACUUM:
10-18 inches of Hg
AMBIENT TEMP:
35O to 125O F (2O - 52O C)
LIQUID TEMP:
125O F (52O C) |
|

MUNICIPAL/INDUSTRIAL
WATER TREATMENT:
-Disinfection of potable water
-Treatment of cooling water to inhibit biological growth and
algae control irrigation systems
MUNICIPAL/INDUSTRIAL WASTE TREATMENT:
-Disinfection of municipal sewage effluent
-High volume chemical feedrates for CSO or BNR processes
CHEMICAL PROCESSING:
-Treatment of industrial wastes from:
-metal finishing
-pulp and paper operations
-chemical plants
-food processing plant discharges
INDUSTRIAL PROCESS WATER:
-Taste and odor control in bottling plants and
breweries
-Tempering water treatment and bleaching in
flour mills
-High purity water in:
-electronics
-pharmaceuticals
-cosmetic industries
SWIMMING POOLS:
-Swimming pool disinfection
|

N/A |
|
|