OSEC
is the U.S. Filter trademark for On Site Electrolytic Chlorination.
This is a system for producing sodium hypochlorite on site
and on demand through the electrolysis of a brine solution.
It is availalbe in standard unit capacities from 6 to 2000lbs.
of equivalent chlorine per day. The system capacity can be
increased by the use of additional modular electrolyzers.
|
 |
 |
Complete
Disinfection System Supply
Gauranteed System Performance and Customer Satisfaction
Virtually Operator-Free Performance
Safety
Alarm Interlocks
Five Year Continuous Use Anode Warranty
Positive
H2 Dilution & Removal
Economical,
Reliable Low Maintenance Operation
Flexible
Installation Configurations To Fit Available Space |
 |
CAPACITY
GPH(LPH):
6 to 2000 lb. per/day
CAPACITY GPH(LPH):
A softener will be provided unless the water is less than 17
mg/l calcium carbonate hardness. The operating temperature of
the feedwater should be between 500 and 800 F. Temperature outside
this range may require additional conditioning. Low water temperatures
will affect the anode surfaces and below 500 F, shorten their
life. For this reason, heat exchangers may be fitted where cold
water conditions are likely to exist. Water consumption is approximately
15 gallons per lb. of available chlorine.
SALT REQUIRMENTS:
It is recommended that the salt be 99.8% pure, vacuum-dried.
A food grade salt is recommended when treating drinking water
supplies. Salt requirments for each pound of equivalent chlorine
produced will vary between 3.0 and 3.9 lbs. depending on feedwater
dilution, salt quality, and temperature.
VOLTAGE:
Control Panel : 120VAC, 60Hz, single phase
Transformer/Rectifier : 440VAC, 60Hz, 3
phase
Typical Power Use
at Electrolyzer: 2.5 kW-hr
per lb of available CL2
AMBIENT TEMP REQUIRMENTS:
40O F (5O C) 104O F (40O C) |
|

MUNICIPAL/INDUSTRIAL
WATER TREATMENT:
-Disinfection of potable water
-Treatment of cooling water to inhibit biological growth and
algae control irrigation systems
MUNICIPAL/INDUSTRIAL WASTE TREATMENT:
-Disinfection of municipal sewage effluent
CHEMICAL PROCESSING:
-Treatment of industrial wastes from:
-metal finishing
-pulp and paper operations
-chemical plants
-food processing plant discharges
INDUSTRIAL PROCESS WATER:
-Taste and odor control in bottling plants and
breweries
-Tempering water treatment and bleaching in
flour mills
-High purity water in:
-electronics
-pharmaceuticals
-cosmetic industries
SWIMMING POOLS:
-Swimming pool disinfection
-CO2 feed for pH control
|

General
OSEC information |
|
|